Crevice Corrosion in a Subsea System — Aspect Before Analysis

Sampling and Analysis — sub-branches

Aspect of a flared tubing, cold deformed at 37°, and the circumferential cracking.
483
ML00167 / Aug.2020
Fatigue of a Flared Tubing Connection
M - Austenitic Stainless SteelP - TubingAp - EngineCd - Mechanical Fatigue
Cm - Aspect Before AnalysisDf - General View
Shaft pinion presenting the bearing surface, with machining markes, from where the thermal spray layer was detached.  The diameter of the 880 mm long shaft in this region is about 75 mm.
426
ML00108 / Dec.2017
Thermal Spray Layer in a Pinion Shaft
M - High Strength Low AlloyP - ShaftAp - EngineCd - Coating Defect
Cm - Aspect Before AnalysisDf - General View