Atlas
About
Contents
Glossary
Facebook
Instagram
LinkedIn
Damage
1 case · 1 image
Crevice Corrosion in a Subsea System — Aspect Before Analysis
Atlas
/
Condition
/ Damage
Application: Refinery
×
Detail focus: Seam
×
clear all
Damage — sub-branches
Corrosion
1
Fabrication Defect
3
Fatigue
1
Results
Sort
Newest
Oldest
Title A-Z
Title Z-A
737
VIEW
ML00177 / Dec.2021
Cr-Mo Seam Welded Tube
M
- CrMo Steel
P
- Longitudinally Seam Welded
Ap
- Fired Heater
Cd
- Not according to spec
Cm
- NItal Etched Macro
Df
- Seam