Crevice Corrosion in a Subsea System — Aspect Before Analysis

Detail of the transverse section of the 4" pipe at the longitudinal seam weld evidencing the leakage position.  The damage appears as a through wall opening.  The pipe thickness is 8 mm and there are no evidences of general corrosion (the SCH 80 corresponds to 8.6 mm) or pitting at the internal surface.
100
ML00140 / May.2019
Preferential Corrosion of Pipe Seam Weld
M - Low Carbon SteelP - Longitudinal Seam Welded PipeAp - ShipCd - Preferential Dissolution
Cm - Transverse Section AspectDf - Leakage