Non Hardened Surface

1 case · 4 images

Crevice Corrosion in a Subsea System — Aspect Before Analysis

The macrography of the transverse tooth section of the SPUR GEAR shows that the surface is not hardened by any process or treatment.
105
ML00027 / Apr.2017
Adhesive Wear of Spur Gear Rack
M - Medium Carbon SteelP - Spur GearAp - Mechanical IndustryCd - Adhesive Wear
Cm - NItal Etched MacroDf - Non Hardened Surface

More from these cases

ML00027 — Adhesive Wear of Spur Gear RackM - Medium Carbon SteelP - Spur GearAp - Mechanical IndustryCd - Adhesive Wear
ML00027 / Apr.2017
Adhesive Wear of Spur Gear Rack
M - Medium Carbon SteelP - Spur GearAp - Mechanical IndustryCd - Adhesive Wear
Cm - Nital Etched Micrography by OMDf - Non Hardened Surface
ML00027 / Apr.2017
Adhesive Wear of Spur Gear Rack
M - Medium Carbon SteelP - Spur GearAp - Mechanical IndustryCd - Adhesive Wear
Cm - NItal Etched MacroDf - Non Hardened Surface
ML00027 / Apr.2017
Adhesive Wear of Spur Gear Rack
M - Medium Carbon SteelP - Spur GearAp - Mechanical IndustryCd - Adhesive Wear
Cm - Nital Etched Micrography by OMDf - Non Hardened Surface