Used
1 case · 2 images
Crevice Corrosion in a Subsea System — Aspect Before Analysis
Microstructure: Coarse Structure ×Capture method: Optical Microscope ×Detail focus: Sampling and Analysis ×clear all
Used — sub-branches

ML00152 / Dec.2018
Low Alloy Steel Pump Shaft
M - High Strength Low AlloyP - ShaftAp - Oil and GasCd - Removed From Service
Cm - Nital Etched Micrography by OMDf - Longitudinal Section
More from these cases

ML00152 / Dec.2018
Low Alloy Steel Pump Shaft
M - High Strength Low AlloyP - ShaftAp - Oil and GasCd - Removed From Service
Cm - Nital Etched Micrography by OMDf - Longitudinal Section