Used

1 case · 1 image

Crevice Corrosion in a Subsea System — Aspect Before Analysis

Used — sub-branches

The macrography of a transverse section shows the carbon steel tube, externally cladded with stainless steel.  The tube was removed from service where it was welded to other tubes to form a wall.
156
ML00056 / May.2018
Seamless Tube Externally Cladded with SS
M - Carbon Steel / Stainless SteelP - CladdingAp - Pulp and PaperCd - Removed From Service
Cm - Kalling Etched MacroDf - Transverse Section