Aspect Before Analysis

2 cases · 3 images

Crevice Corrosion in a Subsea System — Aspect Before Analysis

Flanged case, 640mm long.  The photo presents a general view of the instrumentation system, destroyed after only 6 months in subsea service.  The system was manufactured using only 316 stainless steel and the case was 20 mm thick.
335
ML00122 / Feb.2018
Crevice Corrosion in a Subsea System
M - Austenitic Stainless SteelP - CaseAp - Oil and GasCd - Crevice
Cm - Aspect Before AnalysisDf - General View
ML00098 / Nov.2017
Brittle Fracture of a Casting Lifting Device
M - Low Alloy Medium Carbon QTP - CastingAp - LiftingCd - Brittle Fracture
Cm - Aspect Before AnalysisDf - General View

More from these cases

ML00122 — Crevice Corrosion in a Subsea SystemM - Austenitic Stainless SteelP - CaseAp - Oil and GasCd - Crevice
Aspect of the instrument system after disassembling.  The internal part of the case, where the electronic device was operating, was wet by seawater and failed to send signals to the surface.
258
ML00122 / Feb.2018
Crevice Corrosion in a Subsea System
M - Austenitic Stainless SteelP - CaseAp - Oil and GasCd - Crevice
Cm - Aspect Before AnalysisDf - General View